PIControl
Optional
picontrol
listThe optional picontrol
parameter is a list of preindustrial values. By default, picontrol
is NULL
, which runs the simulation with the default preindustrial values. No matter what preindustrial values are chosen, the model will set the preindustrial surface-ocean alkalinity and deep-ocean dissolved inorganic carbon to values that guarantee preindustrial equilibrium. The values that can be set within the picontrol
list are:
Tatm
,Tdeep
: Preindustrial mean surface-air temperature and mean deep-ocean surface temperature in K. Default values are288
forTatm
and278
forTdeep
.CO2
: Preindustrial molecular number concentration of atmospheric CO2. Default value is280e-6
.Adeep
: Preindustrial alkalinity of the deep ocean in mol/kg. Default value is2.35e-3
.Fwc
,Fws
: Preindustrial rates, in GtC/yr, of weathering of terrestrial carbonates (Fwc
; default of0.1
) and silicates (Fws
; default of0.1
).